IR SERIES INVERTER

1KW-6KW SPECIFICATION

MODEL

HV MODEL

IR

1012E

1024E

1512E

2012E

2024E

2524E

3024E

4048E

5048E

6048E

LINE MODE SPECIFICATIONS

Input Voltage Waveform

Sinusoidal (utility or generator)

Nominal Input Voltage

110Vac / 120Vac / 220Vac / 230Vac

Low Line Disconnect

96Vac± 4% / 155Vac± 2%

Low Line Re-connect

100Vac± 8% / 164Vac± 2%

High Line Disconnect

132Vac± 4% / 272Vac± 2%

High Line Re-connect

127Vac± 4% / 265Vac± 2%

Max AC Input Voltage

270Vrms

Nominal Input Frequency

50Hz/ 60Hz(Auto detection)

Low Line Frequency Re-connect

58+0.3Hz for 60Hz;48+0.3Hz for 50Hz;

Low Line Frequency Disconnect

57+0.3Hz for 60Hz;47+0.3Hz for 50Hz;

High Line Frequency Re-connect

64+0.3Hz for 60Hz;54+0.3Hz for 50Hz;

High Line Frequency Disconnect

65+0.3Hz for 60Hz;55+0.3Hz for 50Hz;

Output Voltage Waveform

As same as Input Waveform

Over-Load Protection(SMPSload)

Circuit breaker

Output Short Circuit Protection

Circuit breaker

Efficiency (Line Mode)

>95%

Transfer Switch Rating

30A

Transfer Time (Ac to Dc)

10ms (typical)

Transfer Time (Dc to Ac)

10ms (typical)

Pass Through Without Battery

Yes

Max Bypass Overload Current

30A

30A

INVERT MODE SPECIFICATIONS

Output Voltage Waveform

Sine wave

Rated Output Power (VA)

1000

1500

1500

2000

2500

3000

4000

5000

6000

Rated Output Power (W)

1000

1500

1500

2000

2500

3000

4000

5000

6000

Power Factor

0~1.0

Nominal Output Voltage (V)

120V/230Vac

Nominal Output Frequency (Hz)

50Hz ± 0.3Hz

Auto Tracking Main Frequency(Hz)

Yes (Following Main first connection)50Hz @48-54Hz ;60Hz @58-64Hz

Output Voltage Regulation

± 10% rms

Nominal Efficiency

>80%

Over-Load Protection(SMPS load)

(110%<load<125%) ± 10%: Fault (shutdown output) after 15 minutes;(125%<load<150%) ± 10%:

Fault (shutdown output) after 60s;Load>150% ± 10%:Fault (shutdown output) after 20s;

Surge Rating (10s)

3000VA

6000VA

7500VA

9000VA

12000VA

15000 VA

18000VA

Capable Of Starting Electric Motor

1 HP

1 HP

1.5HP

2 HP

3 HP

Output Short Circuit Protection

Current limit (Fault after 10s)

Inverter Breaker Size

10A

30A

Nominal DC Input Voltage

12V

24V

12V

24V

24V

48V

48V

Min DC Start Voltage

10V/20V/40V

Low Battery Alarm

10.5Vdc ± 0.3Vdc for 12V battery;21.0Vdc ± 0.6Vdc for 24V battery;42.0Vdc ± 0.6Vdc for 48V battery

Low DC Input Shut-Down

10.0Vdc ± 0.3Vdc for 12V battery;20.0vdc± 0.6Vdc for 24V battery;40.0Vdc± 0.6Vdc for 48V battery

High DC Input Alarm & Fault

16Vdc ± 0.3Vdc for 12V battery;32Vdc ± 0.6Vdc for 24V battery; 64Vdc ± 0.6Vdc for 48V battery

High DC Input Recovery

15.5Vdc ± 0.3Vdc for 12V battery;31.0Vdc ± 0.6Vdc for 24V battery; 62.0Vdc ± 0.6Vdc for 48V battery

Power Saver

Load ≤ 25W (Enabled on “ P/S auto” setting of Remote control)

CHARGE MODE SPECIFICATIONS

Nominal Input Voltage

120V/230Vac

Input Voltage Range

196~243Vac

Nominal Output Voltage

According to the battery type

Nominal Charge Current

35A

35A

45A

65A

35A

40A

45A

35A

40A

50A

Charge Current Regulation

± 5Adc

Battery Initial Voltage

0 – 15.7 Vdc/31.4Vdc/62.8Vdc (can operate with 0V battery)

Charger Short Circuit Protection

Circuit breaker

Over Charge Protection

Bat. V ≥ 15.7Vdc/31.4Vdc/62.8Vdc,beeps 0.5s every 1s & fault after 60s

GENERAL SPECIFICATIONS

Safety Certification

CE

Safety Certification

FCC

Operating Temperature Range

0° C to 40° C

Storage Temperature

15° C below zero to 60° C

Operation Humidity

5% to 95%

Audible Noise

60dB max

Cooling

Forced air, variable speed fan

Size

1012E/1024E/2012E/2024E/2048E/2524E/3012E/3024E/3048E:461X217X179MM4048E/5048E//6048E:636X217X179MM

* Product specifications are subject to change without further notice.

C leverNet ELECTRONIC LIMITED.

Eng_Moataz Mohamed

Tel:+2 0 1111678906 http://www.c nsuez .com E-mail:m ezo7781@gmail.com & moataz_awad@cnsuez.com